ypshimandClaude Haiku 5.5 b962cf1a1c feat(core): bearing-block drawing check and coping rebar C3 (plan C2·C3)
- Drawing check (spec §6.3): an integrated 2500 × 1200 block gives 18@125 = 2250
  along (ends 50 + 75) and 7@125 = 875 across (ends 162.5).
- C3 coping rebar, from RAG/코핑철근.md (2026-10-22 final):
  - C10: 9 bars @300 at 4800–7200 (k_max 4, beyond the Level edge).
  - C9 / C11: 18 bars each @250 outward, ends at 300 and 11700 (end gap 300).
  - Refuses a coping too short for C9 (RB-K01).
  - Side bars C12 5 rows / C13 2 rows at the 42.538 break; C14 38 bars;
    C15 11 bars, C16 22 bars.
- spec §6.4 is older than 코핑철근.md (C10/C9/C11 layout, C12 row count, C14
  dimensions). This follows the final document; spec §6.4 needs an update.
- Not yet: C1–C8 main bars (shape and lengths), the C12/C13 bar lengths and
  shapes, the drawing check of the coping sheet, and the ③ screen.

Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>