The project has one basis: 엑셀 z (default) or 도면 EL.X. On ②, the bearing card lists EL.X, h1 and h2 for each bearing
(per pier), with a button to fill the reference values. With the drawing basis the model takes the drawing EL.X as the
bearing height; the coping tops stay within the 5 mm tolerance, the front block is 164 mm and the back 139 mm (excluding the
pad). The check compares EL.X − h1 − h2 with the Excel-basis coping top. The basis and the drawing values are saved in the
project file (optional fields). Changes regenerate every pier at once.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
On the bearing card, four inputs drive E = h1 + h2 + h3 + h4, L = A + margin, W = B + margin and T1/T2 = T ± L·|S|/2. The
defaults are the drawing values, so every row gives back the drawing values; changed rows are marked. The values are screen
state for now and do not change the model or the project file (Q16 stays open).
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
The solplate tapers along the bridge axis. T is the centre thickness (30), T1 the thickness on the 교각축 직각 (−) side
(38) and T2 on the (+) side (22); T1 + T2 = 2T. The table's T column had shown the (−) side value, so T is now 30 on every
row. A test checks T1 + T2 = 2T.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
The P1 상세도 ELEVATION TABLE and 솔플레이트 TABLE are shown on the bearing card. The model does not use them (Q16). The
ELEVATION table compares the drawing's coping top (EL.X − E) with the model's coping top; the difference is a constant
0.211 m on all ten bearings. The solplate table checks T1 and T2 against T ± L·|S|/2 with the 공통 규칙 T = 30 mm; all
rows match. Tests check E = h1+h2+h3+h4, L and W, the T1/T2 rule, and the constant offset.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>