ypshimandClaude Haiku 5.5 e4e141c801 feat(rebar,view): 받침 기준 — project-wide choice between Excel z (default) and drawing EL.X, with per-bearing drawing input on ②
The project has one basis: 엑셀 z (default) or 도면 EL.X. On ②, the bearing card lists EL.X, h1 and h2 for each bearing
(per pier), with a button to fill the reference values. With the drawing basis the model takes the drawing EL.X as the
bearing height; the coping tops stay within the 5 mm tolerance, the front block is 164 mm and the back 139 mm (excluding the
pad). The check compares EL.X − h1 − h2 with the Excel-basis coping top. The basis and the drawing values are saved in the
project file (optional fields). Changes regenerate every pier at once.

Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
2026-10-23 14:25:44 +09:00
ypshimandClaude Haiku 5.5 553c696638 feat(view): bearing 공통 규칙 inputs (mortar h2, bearing h3, solplate T, margin) and recalculated E, L, W, T1, T2
On the bearing card, four inputs drive E = h1 + h2 + h3 + h4, L = A + margin, W = B + margin and T1/T2 = T ± L·|S|/2. The
defaults are the drawing values, so every row gives back the drawing values; changed rows are marked. The values are screen
state for now and do not change the model or the project file (Q16 stays open).

Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
2026-10-23 14:12:36 +09:00
ypshimandClaude Haiku 5.5 64795e0a19 fix(view): solplate reference shows centre T = 30 with the (−) and (+) side thicknesses (taper along the axis)
The solplate tapers along the bridge axis. T is the centre thickness (30), T1 the thickness on the 교각축 직각 (−) side
(38) and T2 on the (+) side (22); T1 + T2 = 2T. The table's T column had shown the (−) side value, so T is now 30 on every
row. A test checks T1 + T2 = 2T.

Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
2026-10-23 14:10:23 +09:00
ypshimandClaude Haiku 5.5 ee6848c418 feat(view): bearing reference tables on ② (drawing values, read-only, not used in the model)
The P1 상세도 ELEVATION TABLE and 솔플레이트 TABLE are shown on the bearing card. The model does not use them (Q16). The
ELEVATION table compares the drawing's coping top (EL.X − E) with the model's coping top; the difference is a constant
0.211 m on all ten bearings. The solplate table checks T1 and T2 against T ± L·|S|/2 with the 공통 규칙 T = 30 mm; all
rows match. Tests check E = h1+h2+h3+h4, L and W, the T1/T2 rule, and the constant offset.

Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>