- Columns closer than one footing length (10400) share a 일체기초 whose
length is the outer-column distance + 10400, centred between them (spec §4.6).
- Pile grid is computed from each footing's length (rows across 8150,
pile count along the length from (length − 1400) / 2250 + 1).
- Blinding concrete follows each combined footing.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
- Multi-column coping (2·3주형): underside between columns drops 300 below
Level with 300 × 300 haunches (spec §4.5, Q3 추천안).
- Steel pipe pile diameter 609.6 mm (spec §4.5, Q5 추천안).
- Direct foundation keeps the 100 mm blinding concrete (Q4 추천안, test added).
- W03: bearing centre closer than half a block width to a step boundary.
- W04: block footprint outside the coping plan.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>