The coping middle level is (Level underside + step top)/2. P3's top and P6's upper limit are this level, and e_top is the
step top minus it (P1: 1322, replacing the 1623 reverse-engineered value). On P1 P3 goes from 38 to 39 ties and P6 stays at
8 levels. With taper h2 = 3000 the middle level is 13275: P3 37 ties, P6 8 levels (32 bars), e_top 2072.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
e_P1 is no longer an input: P1 top = C3 (lowest coping top − 127 − 2·57.2 = 43.170) − 100 = 43.070, so e_P1 = step top −
43.070 = 485 mm. The P1 top moves from 15147 to 14862 mm; the top piece shortens by 285 mm. Couplers are placed at k·3000
with at least 2500 mm below the P1 top (a value to confirm). On P1 the coupler count stays at four (3, 6, 9, 12 m). P2 and
the tie top do not change.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
- A P4 is deleted when |z_P4 − z_bar| < (d_P4 + d_bar)/2 against B5 and B1
(the 확대기초 top layer, from the 상면). B11/B12 are not checked (Q-C9 무시).
- The P6 crossties start from the first kept P4.
- Tests: the document's example keeps all 8; B5 moved to −70 deletes the P4 at
−60; a P4 just outside the limit is kept.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
- Nominal bar diameters (H29 28.6, S32 31.8, …) as used by the documents. With
them, C7/C8 l_s = 1.3·l_d(28.6, fck 27) = 1717.6, which is the document's 1717.
- C1–C8 (코핑철근.md §5): width layout 127 · 110.5 · 21@125 · 110.5 · 127 with 24
bars (12 + 12); heights 43.284 / 43.227 / 43.170; top bar lengths 12744 /
12629.6 / 12515.2; bottom pieces ≈ 7448.
- C4 (기둥철근.md): P1 r 875 and P2 r 843.2; couplers P1 +3/6/9/12 m, P2 +150;
230 + 230 main pieces and 368 couplers; tie radius 900.45; P3 38 at @300 from
2.340; P5 19 at @120; P4 8 at @120 from −0.060; P6 8 levels × 4 = 32, length
≈ 2071.
- Not yet: C4 interference checks (P4 vs B11, Q-C9), bar lengths of P3/P5/P4
and coupler shapes, the coping/column drawing checks, and the ③ screen.
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>