Commit Graph
2 Commits
Author SHA1 Message Date
ypshimandClaude Haiku 5.5 17b5b24682 feat(core,view): per-row pile counts 열별 본수 (plan C4)
- A 열 is one row across the footing width; each has its own count along the
  length. Default floor((L − 1400) / 2250) + 1 per 열, as in spec §4.6.
- Counts are validated: one per 열, whole numbers 2–30. Spacing below the
  2250 mm minimum is shown as a warning, not refused (the plan's 6본 → 5@1800
  example).
- PierInput gains an optional pileRows; absent means the defaults, so existing
  files and the P1 results are unchanged.
- Change tracking compares arrays by value; 열별 본수 can be reverted and
  copied (copy item off by default).
- The footing card has −/+ per 열 with spacing, total, and the display string.
- Tests: defaults 4열 × 5본 = 20 and the 1단계 text; 6본 → 5@1800; limits;
  model-level 21 piles.
- Not verified in a browser.

Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
2026-10-22 10:34:39 +09:00
ypshimandClaude Haiku 5.5 4accf1f3be feat(core): attribute-copy engine (plan C7)
- planCopy previews the changes and the skipped items for one target; applyCopy
  applies exactly the planned changes.
- Default selection copies only the coping width; coping length and pile length
  are off by default (spec §9). Pile items are skipped when the foundation type
  differs. Coordinates, IPs, bearings and elevations are not in any item.
- Equal values are not counted, so the preview count equals the applied count.

Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
2026-10-22 09:59:48 +09:00